32099: Length of data section of module acp10cfg is too small

Info: Number of data section
Data type: UINT

Description:
If a section of the module ACP10CFG is too small for the data to be evaluated, this error is displayed.

Note:
If this error occurs, the following error with this error number in the binary data is entered in the Logger:
- 10550: Read NC CFG module: NC manager error in 'Binary Data'

In addition, the following error with the number of the affected data section in the binary data is entered in the Logger:
- 10551: Read NC CFG module: Status for NC manager error in 'Binary Data'

Reaction:
Initialization of the NC software is aborted. No NC object can be operated.

Cause/Remedy:
Re-create the module acp10cfg and transfer it to the target.
Change of the NC software version.
Change of the Automation Studio version.