| Info: | Status of plAcycWrite() |
| Data type: | UINT |
Description:
To read a parameter value via the broadcast channel, the NC manager sends an acyclic Read Request frame by calling the function plAcycWrite(). This error number is output if an error occurs with this procedure.
Reaction:
Resets the interface of the corresponding acyclic POWERLINK broadcast channel.
Cause/Remedy:
The exact cause can be determined from the status of plAcycWrite().