32273: ACOPOS coupling: The NC object of the send data is invalid

Info:
Data type:

Description:
Only NC objects with type "ncAXIS" or "ncV_AXIS" which belong to the ACP10 software are allowed as NC object of the send data.

Reaction:
Processing of the corresponding NC action is aborted.

Cause/Remedy:
Specify a valid NC object of the send data.