| Info: | Additional info |
| Data type: | UDINT |
Description:
One or more enabled functions are not supported by the hardware.
The additional information (Info1) shows the not supported function(s):
0x00000001 .. SLT
0x00000002 .. SBT
0x00000004 .. SSO
Offset information for safety logger:
binary data[20..17]: Info1
Reaction:
The module changes into Fail Safe state.
Cause/Remedy:
Change the SafeMOTION hardware.
Check the enabled safety functions in SafeDesigner!