35021: SMC FS: Internal error, Cross communication of Encoder state machine

Info: EnDat state machine
Data type: UDINT

Description:
Internal runtime error during MFW cross communication. The states of the Encoder state machines are different.

Reaction:
The module changes into Fail Safe state.

Cause/Remedy:
Call technical support!