35104: SMC FS: Internal error, FPGA communication

Info: Additional info
Data type: UDINT

Description:
Internal runtime error during FPGA communication. The states of the FPGACom state machines are different.

The additional information (Info1) shows the details:
0x0000 ... Requested register ID not valid.
0x0001 ... Write buffer overflow.
0x0002 ... INIT DONE not valid.
0x0003 ... Length of requested register ID not supported.
0x0004 ... CRC of data from FPGA is wrong.
0x0005 ... Consecutive number not equal to expected value.
0x0006 ... Clock drift detected.
0x0007 ... FPGA ID not valid.
0x0008 ... FPGA version not valid.
0x0009 ... CRAM CRC is wrong.
0x000A ... Cyclic write buffer not valid.
0x0010 ... FPGA module register: Default value of invalid
0x0011 ... FPGA module register: CRC_S of configuration register invalid
0x0021 ... FPGA module register: PULPS status invalid
0x0022 ... FPGA module register: Core status invalid
0x0030 ... FPGA module register: Functional test of maximum limit clock drift monitoring fail
0x0031 ... FPGA module register: Functional test of minimum limit clock drift monitoring fail
0x0040 ... FPGA module register: Functional test of SEU check fail (port error)
0x0041 ... FPGA module register: Functional test of SEU check fail (status error)
0x0042 ... FPGA module register: Functional test of SEU check fail (timeout) */
0x0050 ... FPGA module register: Functional test of minimum limits SYNC monitoring fail
0x0051 ... FPGA module register: Functional test of nominal limits SYNC monitoring fail
0x0052 ... FPGA module register: Functional test of maximum limits SYNC monitoring fail
0x0053 ... invalid functions configured
0x0060 ... FPGA axis register: CRC_S of configuration register invalid */
0x0080 ... FPGA axis register: Default value of invalid */
0x0090 ... Invalid sampling between Slot 1 and Slot 2
0x0091 ... Invalid sampling between Slot 2 and Slot 3
0x0092 ... Invalid sampling between Slot 3 and Slot 4
0x0093 ... Invalid sampling between Slot 4 and Slot 1

Offset information for safety logger:
binary data[20..17]: Info1

Reaction:
The module changes into Fail Safe state.

Cause/Remedy:
Call technical support!