35151: SMC FS: Additional safety parameters: Placeholder enable bit is set

Info: Additional info
Data type: UDINT

Description:
An enable bit of a placeholder of the safe machine options structure is set.

The additional information (Info1) contains the index of this placeholder variable

Offset information for safety logger:
binary data[20..17]: Info1

Reaction:
The module changes into Fail Safe state.

Cause/Remedy:
Check the functional application!