35192: SMC: Current sum exeeded tolerance range

Info: Current sum [uA]
Data type: DINT

Description:
During the current measurement the actual current sum (Iu + Iv + Iw) was too high.
The current sum is monitored to check the proper function of the current measurement.

The additional information (Info1) shows the actual current sum (first logger entry) resp. the current sum limit (second logger entry) in ľA.

Offset information for safety logger:
binary data[20..17]: Info1

Reaction:
A warning is created.
For SSO encoders, the status S_NotErrENC / S_Status_EncStatus is set to FALSE.
The status S_SafetyStatusSBT/S_Status_SBT is set to FALSE
The status S_Status_SLT is set to FALSE

Cause/Remedy:
Motor phase and ground conductor switched. -> Check the wiring!
Housing short between motor phase and housing. -> Check the motor!
Current measurement defective. -> Call technical support!