| Info: | Actual current [uA] |
| Data type: | DINT |
Description:
During the Safe Brake Test the actual current of phase V exceeded the current sensor measurement range.
The additional information (Info1) shows the actual current of phase V in ľA.
Offset information for safety logger:
binary data[20..17]: Info1
Reaction:
A warning is created.
The Safe Brake Test status is cleared.
Cause/Remedy:
Set current value jump. -> Check the functional brake test sequence!
Motor defective. -> Check the motor!
Current measurement defect. -> Call technical support!