| Info: | |
| Data type: |
Description:
See error number 6029.
Reaction:
See error number 6029.
Cause/Remedy:
Holding brake voltage supply too high.
ACOPOS defective
The parameter MOTOR_BRAKE_VOLT_MAX is set to a too low value. Only relevant for ACOPOS modules with configurable overvoltage monitoring.