7093: Encoder: HIPERFACE DSL: Online status: Bit 12: FIX1: Bit not '1'

Info: Encoder
Data type: USINT

Description:
This status is reported by the HIPERFACE DSLŪ Master IP-Core. More information can be found in the encoder data sheet or the HIPERFACE DSLŪ specification.
Excerpt from the HIPERFACE DSLŪ specification for Online Status Bit 12:
This bit always gives a "1". For SPI interfaces, this is used for checking the spi_miso pin for stuck-at-'0' faults.

Reaction:
See error number 7030.

Cause/Remedy:
See encoder data sheet or HIPERFACE DSLŪ specification.