Option: HotWater Unit (06A746)

This function is used to interface with an additional Hot Water Unit (mold temperature control unit).
At the moment, this option is implemented only for injection B

1. Machine Option

2. User Settings (Injection Settings page)

  • Activation
    • The function can be enabled or disabled through the checkbox Enable HotWater Unit.
  • IOs : The interface consists of 1 digital input 그리고 1 digital output.
    • Digital Input (injection interlock)
      • Signal: gDI.HotWaterUnitReady
      • Injection operation is only allowed when this input signal is TRUE.
    • Digital Output
      • A 1-second pulse signal is generated at the timing selected in the dropdown menu.
      • Available options:
        • Injection/Hold End
        • Start Clamp Open