{"id":3497,"date":"2025-10-23T15:14:19","date_gmt":"2025-10-23T15:14:19","guid":{"rendered":"https:\/\/www.woojin.help\/?p=3497"},"modified":"2026-03-03T09:09:28","modified_gmt":"2026-03-03T09:09:28","slug":"machine-setup-parameters-te-a5-imc510","status":"publish","type":"post","link":"https:\/\/www.woojin.help\/ko\/machine-setup-parameters-te-a5-imc510\/","title":{"rendered":"Machine Setup Parameters (TE-A5, IMC510)"},"content":{"rendered":"<div class=\"pdfprnt-buttons pdfprnt-buttons-post pdfprnt-top-right\"><\/div>\n<h2 class=\"wp-block-heading\">Clamp<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Parameter<\/td><td>Value Range<\/td><td>Description<\/td><\/tr><tr><td>General<br>&#8211; Sensor Type<br>&#8211; Actuator Type<br>&#8211; 1st Step Release Pressure<br>&#8211; End Release Pressure<br>&#8211; Maximum Sensor Pressure<br>&#8211; Minimum Voltage (Sensor)<br>&#8211; Maximum Voltage (Sensor)<\/td><td><br>Endat<br>Electric<br>25 bar<br>10 bar<br>Machine TON * 10<br>0 mV<br>10000 mV<\/td><td><br><br><br><br><br>Need a parameters only for main sensor, the other sensors are optional<br><br><\/td><\/tr><tr><td>Mold Open<br>&#8211; Accel\/Decel\/End Decel Velocity Rate<\/td><td><br>500 &#8211; 1500 mm\/s2<\/td><td><br><\/td><\/tr><tr><td>Mold Close<br>&#8211; Slow Velocity Locking Mold<br>&#8211; Maximum Pressure(MP)<br>&#8211; Maximum Pressure(Lock)<br>&#8211; Mold HP Maximum Start Position<\/td><td><br>50 &#8211; 150 mm\/s<br>&lt; 50%<br>Later<br>5 mm<\/td><td><br>Speed during automatic mold height (after reached 0 tonnage point)<br>Maximum allowed force % for mold protection step<br>Used for Hydraulic machine \/ Machine Test funciton<br>Maximum limitation of mold lock position<\/td><\/tr><tr><td>End Position Controller<br>&#8211; PID Position Mode<br>&#8211; Proportional Gain &#8211; Kp<br>&#8211; Intergral Ampl. &#8211; Ki<br>&#8211; Derivative Ampl. &#8211; Kd<br>&#8211; Max Output Controller<br>&#8211; Windup Protection<\/td><td><br>Position Mode V1<br>100<br>1<br>2<br>75<br>100<\/td><td>(PID Position controller at the stop position)<br><br><br><br><br><br><\/td><\/tr><tr><td>Mold Height General<br>&#8211; Sensor type<br>&#8211; Actuator type<br>&#8211; Minimum Stroke<br>&#8211; Maximum Stroke<br>&#8211; Filter Time<br>&#8211; Mold open in auto mold height<br>&#8211; Max Pressure Zero Tonnage point<br>&#8211; Min PositionMH Adjust High Pressure<\/td><td><br>POT<br>Electric<br>Machine Data<br>Machine Data<br>40 ms<br>100 ~ 200 mm<br>20 &#8211; 50 bar<br>3 ~ 10 mm<\/td><td>(General Mold height parameters)<br><br><br><br><br>Filter time for speed<br>Mold open distance during automatic mold height<br>Maximum pressure at the zero tonnage point<br>Minimum mold locking position (max tonnage need higher distance)<\/td><\/tr><tr><td>Mold Height Parameters<br>&#8211; Velocity after MH Touch Point<\/td><td><br>15-30 mm\/s<\/td><td><br>Slower Moldheight Speed after zero tonnage point detected.<\/td><\/tr><tr><td>Tonnage Data<br>&#8211; Pulse per MH rotation [pulse]<br>&#8211; Stroke per MH rotation<br>&#8211; Tolerance for MH Adjust<br>&#8211; Clamp Force Sensor<br>&#8211; Calibration Increments Backward<br>&#8211; Calibration Increments Forward<\/td><td><br>Machine Data<br>Machine Data<br>100-200 kN<br>Use<br>75<br>100<\/td><td>(Parameters for Auto Moldheight Calibration \/ Adjustment)<br>Pulse per MH 1 rotation [Pulse]<br>Mold Stroke per MH 1 rotation [mm]<br>Allowed tolernace for mold height result[kN]<br>Use of Clamp force sensor<br>MH backward trial step for Auto MH Calibration <br>MH forward trial step for Auto MH Calibration<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Ejector<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Parameter<\/td><td>Value Range<\/td><td>Description<\/td><\/tr><tr><td>General<br>&#8211; Sensor Type<br>&#8211; Actuator Type<\/td><td><br>Endat<br>Electric<\/td><td><\/td><\/tr><tr><td>Ejector Retract \/ Advance<br>&#8211; Accel\/Decel\/End Decel Velocity Rate<br>&#8211; Setting Mode Velocity<br>&#8211; Setting Mode Pressure<br>&#8211; Position Tolerance<br>&#8211; Maximum Velocity<br>&#8211; Maximum Pressure<\/td><td><br>2000 mm\/s2<br>30-50 mm\/s<br>30 %<br>1 &#8211; 2 mm<br>Machine Data<br>????<\/td><td><\/td><\/tr><tr><td>End Position Controller (Retract\/Advanced)<br>&#8211; PID Position Mode<br>&#8211; Proportional Gain &#8211; Kp<br>&#8211; Intergral Ampl. &#8211; Ki<br>&#8211; Derivative Ampl. &#8211; Kd<br>&#8211; Max Output Controller<br>&#8211; Windup Protection<\/td><td><br>Position Mode V1<br>100<br>1<br>2<br>75<br>100<\/td><td>(PID Position controller at the stop position)<br><br><br><br><br><br><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-left\">Injection<\/h2>\n\n\n\n<h4 class=\"wp-block-heading\">General<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Parameter<\/td><td>Value Range<\/td><td>Description<\/td><\/tr><tr><td>General<br>&#8211; Sensor Type<br>&#8211; Actuator Type<br>&#8211; Maximum Force<br>&#8211; Maximum Sensor Pressure<\/td><td><br>Endat<br>Electric<br>kN<br>kg\/cm2<\/td><td><br><br><br>Machine Sensor Data<br>Calculated from Maximum Force &amp; Screw Area<\/td><\/tr><tr><td>Injection Part Display Settings<br>&#8211; Screw Diameter<\/td><td><br>mm<\/td><td><br>Machine Data, Used for calculation of Maximum Presusre<\/td><\/tr><tr><td>Specific Injection Parameter<br>&#8211; Maximum Specific Velocity<br>&#8211; Maximum Specific Pressure<br>&#8211; Maximum Inject Volume<\/td><td><br><br><br><\/td><td><br><br><br><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Injection<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Parameter<\/td><td>Value Range<\/td><td>Description<\/td><\/tr><tr><td>Injection Parameters<br>&#8211; Accel\/Decel\/End Decel Velocity Rate<br>&#8211; Setting Mode Velocity<br>&#8211; Setting Mode Pressure<br>&#8211; Position Tolerance<br>&#8211; Maximum Velocity<br>&#8211; Maximum Pressure<\/td><td><br>1000-2000 mm\/s2<br>10-50 mm\/s<br>20-30 %<br>1 &#8211; 3 mm<br>[mm\/s]<br>1500-2500 bar<\/td><td>(General Injection Parameters)<br><br><br><br><br>Machine Data<br>Machine Data<\/td><\/tr><tr><td>Holdon Pressure Controller<br>&#8211; Proportional Gain &#8211; Kp<br>&#8211; Integralverst. &#8211; Ki<br>&#8211; Derivative Ampl. &#8211; Kd<br>&#8211; Hold On Pressure Ramp<br>&#8211; Sampling time<\/td><td><br>0.5 &#8211; 3  (1)<br>5 &#8211; 15  (5)<br>(0)<br>3000-5000  (3000)<br>0.008 sec<\/td><td>(Holdon Pressure Controller (PID))<br><br>(it is Ki, not Tn)<br><br>[0.1 bar\/s]<br><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Decompression<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Parameter<\/td><td>Value Range<\/td><td>Description<\/td><\/tr><tr><td>Decompression Setting (General)<br>&#8211; Minimum Decomp before<br>&#8211; Decomp1 Pressure<br>&#8211; Decomp2 Pressure<br>Forced Decompression Setting<br>&#8211; Forced Decompression Enable<br>&#8211; Forced Decomp. Distance<br>&#8211; Forced Decomp. Speed<br>&#8211; Forced Decomp. Pressure<\/td><td><br>5 &#8211; 10 mm<br>30-40 %<br>30-40 %<br><br>Enable<br>2-5 mm<br>50-100 mm\/s<br>30-40 %<\/td><td><br><br><br><br>(Forced Decompresion)<br><br>Maximum moving distance<br><br><\/td><\/tr><tr><td>Decompression Parameters (Inject)<br>&#8211; Accel\/Decel\/End Decel Velocity Rate<br>&#8211; Setting Mode Velocity<br>&#8211; Setting Mode Pressure<br>&#8211; Position Tolerance<br>&#8211; Maximum Velocity<br>&#8211; Maximum Pressure<\/td><td><br>500-1000mm\/s2<br>10-50 mm\/s<br>30-40%<br>1-3 mm<br>mm\/s<br>????<\/td><td>(Decompresison General Parameters)<br><br><br><br><br>Machine Data<br><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Plasticizing<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Parameter<\/td><td>Value Range<\/td><td>Description<\/td><\/tr><tr><td>Charge Main Pressure Setting<br>&#8211; Charge Pressure<\/td><td><br>????<\/td><td><br>(Recipe data)<\/td><\/tr><tr><td>Charge Parameters<br>&#8211; Accel\/Decel\/End Decel Velocity Rate<br>&#8211; Setting Mode Velocity<br>&#8211; Setting Mode Pressure<br>&#8211; Maximum Velocity<\/td><td><br>10000 -30000 rpm\/s2<br>Not used<br>Not used<br>[rpm]<\/td><td>(General Plasticizing Parameters)<br><br>Use same as manual mode<br>Use same as manual mode<br>Machine Data<\/td><\/tr><tr><td>Back Pressure Controller<br>&#8211; Proportional Gain &#8211; Kp<br>&#8211; Integralverst. &#8211; Ki<br>&#8211; Derivative Ampl. &#8211; Kd<br>&#8211; Sampling time<br>&#8211; Maximum Negative Velocity<br>&#8211; Backpressure Maximum<br>&#8211; Backpressure Set Limit<\/td><td><br>1-5  (1)<br>5-15 (10)<br>(0)<br>0.008 sec<br>200 &#8211; 500 rpm<br>370 bar<br>350 bar<\/td><td>Back Pressure Controller (PID)<br><br><br><br><br><br>Pressure maximum during intrusion,purge<br>Maximum value for user setting<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Drive Parameters<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Parameter<\/td><td>Value Range<\/td><td>Description<\/td><td>Axis<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Groupbox Drive Tuning:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>&#8211; Velocity Controller Kp<\/td><td>0,5 &#8211; 4<\/td><td>Responsible for the P-Part of the Drive PI-Controller<\/td><td>IP1, IP2, PL, CU1, CU2, EJ<\/td><\/tr><tr><td>&#8211; Velocity Controller Tn<\/td><td>5-50<\/td><td>Responsible for the I-Part of the Drive PI-Controller<\/td><td>IP1, IP2, PL, CU1, CU2, EJ<\/td><\/tr><tr><td>&#8211; Velocity Filter tFilter Speed<\/td><td>0,6-1<\/td><td>Constant for the Speed Control filter time<\/td><td>IP1, IP2, PL, CU1, CU2, EJ<\/td><\/tr><tr><td>&#8211; dnUp\/dnDown<\/td><td>5000-10000<\/td><td>Maximum change of rpm\/s allowed, should not be lower than acc or decc, otherwise there will be an overshoot to the target position<\/td><td>IP1, IP2, PL, CU1, CU2, EJ<\/td><\/tr><tr><td>&#8211; Position Controller Kp<\/td><td>&#8211;<\/td><td>not used at the moment, only important for CSP<\/td><td>&#8211;<\/td><\/tr><tr><td>&#8211; Max.Torque%<\/td><td>Tag 3: 300%<br>Tag 3.1: 100%<\/td><td>Maximum Torque allowed during movement<br>Tag 3: 300% = 3x rated Torque<br>Tag 3.1: 100% = 3x rated Torque<\/td><td>IP1, IP2, PL, CU1, CU2, EJ<\/td><\/tr><tr><td>&#8211; Stall.Torque%<\/td><td>Tag 3: 100%<br>Tag 3.1: 33%<\/td><td>Maximum Torque allowed during standstill<br>Tag 3: 100% = 1x rated Torque<br>Tag 3.1: 33% = 1x rated Torque<\/td><td>IP1, IP2, PL, CU1, CU2, EJ<\/td><\/tr><tr><td>&#8211; Mode of operation<\/td><td>9: cyclic velocity<\/td><td>We only use CSV<\/td><td>IP1, IP2, PL, CU1, CU2, EJ<\/td><\/tr><tr><td>&#8211; Drive Terminal 2<\/td><td><\/td><td>Select this, if the chosen axis is the second on a multi ax drive<\/td><td>IP1, IP2, PL, CU1, CU2, EJ<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Groupbox Gear Settings:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>&#8211; Increments per Round<\/td><td>65536<\/td><td>360 Degree turn on the motor equals 65536 increments<\/td><td>IP1, IP2, PL, CU1, CU2, EJ<\/td><\/tr><tr><td>&#8211; Gear Ratio: Teeth Drive Wheel<\/td><td>&#8211;<\/td><td>Insert from mechanical datasheet<\/td><td>IP1, IP2, PL, CU1, CU2, EJ<\/td><\/tr><tr><td>&#8211; Gear Ratio: Teeth Driven Wheel<\/td><td>&#8211;<\/td><td>Insert from mechanical datasheet<\/td><td>IP1, IP2, PL, CU1, CU2, EJ<\/td><\/tr><tr><td>&#8211; Gear Ratio: Spindl Lead<\/td><td>&#8211;<\/td><td>Insert from mechanical datasheet<\/td><td>IP1, IP2, PL, CU1, CU2, EJ<\/td><\/tr><tr><td>&#8211; Enable reverse<\/td><td>0 = clockwise<br>1 = counterclockwise<\/td><td>Enable this if the motor is reversed (only EJ as far as i know)<\/td><td>IP1, IP2, PL, CU1, CU2, EJ<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Groupbox Slave Syncronize Controller:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>&#8211; Synchronize Controller Kp<\/td><td>&#8211;<\/td><td>currently not in use, we use Torque Follower<\/td><td><\/td><\/tr><tr><td>&#8211; Synchronize Controller Ki<\/td><td>&#8211;<\/td><td>currently not in use, we use Torque Follower<\/td><td><\/td><\/tr><tr><td>&#8211; Synchronize Controller Kd<\/td><td>&#8211;<\/td><td>currently not in use, we use Torque Follower<\/td><td><\/td><\/tr><tr><td>&#8211; Sampling time<\/td><td>&#8211;<\/td><td>currently not in use, we use Torque Follower<\/td><td><\/td><\/tr><tr><td>&#8211; Maximum Tolerance<\/td><td>&#8211;<\/td><td>currently not in use, we use Torque Follower<\/td><td><\/td><\/tr><tr><td>&#8211; u max neg.<\/td><td>&#8211;<\/td><td>currently not in use, we use Torque Follower<\/td><td><\/td><\/tr><tr><td>&#8211; u max pos.<\/td><td>&#8211;<\/td><td>currently not in use, we use Torque Follower<\/td><td><\/td><\/tr><tr><td>&#8211; Master Slave Controller<\/td><td>Torque Follower<\/td><td>for coupled axis select torque follower <\/td><td>IP2, CU2<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Groupbox Supply Settings:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>&#8211; Nominal Voltage<\/td><td>&#8211;<\/td><td>only change this value if User Setting is selected for selection of powersupply<\/td><td>IP1<\/td><\/tr><tr><td>&#8211; selection of powersupply<\/td><td>&#8211;<\/td><td>select from dropdown depending on the country<br>Austria = 3&#215;400 V <\/td><td>IP1<\/td><\/tr><tr><td>&#8211; Phases<\/td><td>three-phases<\/td><td>select from dropdown depending on how many phases are connected (will almost always be three-phases)<\/td><td>IP1<\/td><\/tr><tr><td>&#8211; Disable Choke Watch<\/td><td>0 (ON) = Temperature monitoring of the choke enabled<br>1 (OFF) = Temperature monitoring of the choke disabled<\/td><td>Deactivates the temperature monitoring (Klixon) of the mains choke<\/td><td>IP1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Groupbox Injection Pressure Limit Controller: During injection PID controller to limit the injection pressure<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>&#8211; Kp<\/td><td><\/td><td><\/td><td>IP1<\/td><\/tr><tr><td>&#8211; Tn<\/td><td><\/td><td><\/td><td>IP1<\/td><\/tr><tr><td>&#8211; Tv<\/td><td><\/td><td><\/td><td>IP1<\/td><\/tr><tr><td>&#8211; T1<\/td><td><\/td><td><\/td><td>IP1<\/td><\/tr><tr><td>&#8211; nRev<\/td><td>-500 ~ -1000<\/td><td>Reverse rotation limit<\/td><td>IP1<\/td><\/tr><tr><td>&#8211; Filter fAct<\/td><td>0.001<\/td><td>Pressure filter<\/td><td>IP1<\/td><\/tr><tr><td>&#8211; Filter fSetUp<\/td><td>0.001<\/td><td>Pressure filter<\/td><td>IP1<\/td><\/tr><tr><td>&#8211; Filter fSetDown<\/td><td>0.001<\/td><td>Pressure filter<\/td><td>IP1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\"><\/h4>\n","protected":false},"excerpt":{"rendered":"<p>Clamp Parameter Value Range Description General&#8211; Sensor Type&#8211; Actuator Type&#8211; 1st Step Release Pressure&#8211; End Release Pressure&#8211; Maximum Sensor Pressure&#8211; [&hellip;]<\/p>\n","protected":false},"author":13,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[318,381],"tags":[],"class_list":["post-3497","post","type-post","status-publish","format-standard","hentry","category-imm-a5","category-imm-a5-manual"],"_links":{"self":[{"href":"https:\/\/www.woojin.help\/ko\/wp-json\/wp\/v2\/posts\/3497","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.woojin.help\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.woojin.help\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.woojin.help\/ko\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/www.woojin.help\/ko\/wp-json\/wp\/v2\/comments?post=3497"}],"version-history":[{"count":16,"href":"https:\/\/www.woojin.help\/ko\/wp-json\/wp\/v2\/posts\/3497\/revisions"}],"predecessor-version":[{"id":3885,"href":"https:\/\/www.woojin.help\/ko\/wp-json\/wp\/v2\/posts\/3497\/revisions\/3885"}],"wp:attachment":[{"href":"https:\/\/www.woojin.help\/ko\/wp-json\/wp\/v2\/media?parent=3497"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.woojin.help\/ko\/wp-json\/wp\/v2\/categories?post=3497"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.woojin.help\/ko\/wp-json\/wp\/v2\/tags?post=3497"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}