| Info: | Encoder |
| Data type: | USINT |
Description:
This status is reported by the HIPERFACEŽ encoder. More information can be found in the data sheet or HIPERFACEŽ encoder specification.
Excerpt from the HIPERFACEŽ specification:
At startup, "Analog limit values not available" indicates that one of the following values stored in nonvolatile memory was corrupted:
- Temperature warning range
- LED current warning range
- Synchronization check warning range
- Other diagnostic ranges
The indication will be stored in the error stack along with the "Internal checksum error" (see error number 39516).
Position output is locked if this fault was detected. A "Read position" or "Set position" command will always receive a slave error response with this fault code.
Reaction:
None
Cause/Remedy:
See encoder data sheet or HIPERFACEŽ specification.