Clamp Stopper Release Function User Manual(VHG5)

  • Author: Park Wihoon
  • Version: REV-1.0
  • Date: 2026-03-09
  • Department: Control Design Team 1
  • Usage: Internal Use Only

1. Overview

This manual describes the configuration and operation of the Clamp Stopper Release Function.

The function is used to resolve a condition where the clamp stopper is stuck due to missing unlock signals.


2. Function Structure

2.1 Monitoring Time Setting (Rotary Page)

  • Location: Rotary Setting Page
  • Parameter: Clamp Stopper Monitoring Time

Description

  • If Left/Right Clamp Stopper Unlock signals are not detected:
  • The system determines that the stopper is stuck.
  • A timer starts.
  • If the timer exceeds the configured monitoring time:
  • An alarm is triggered.

Recovery Procedure

  1. Alarm 발생
  2. Alarm Reset 수행
  3. Mold Open Key 재입력
  4. Clamp 상승 → Stopper 끼임 해제

3. Operation Conditions

  • This function is available only in Manual Mode
  • Initial setup requires monitoring time configuration

4. Release Operation Setting (Expert Page)

  • Location: Expert Setting Page

Adjustable Parameters

ParameterDescription
Release SpeedSpeed applied during stopper release
Release PressurePressure applied during stopper release
Release DistanceMovement distance for stopper release

5. Release Recipe Configuration

The stopper release operation can be customized using the following parameters:

  • Speed
  • Pressure
  • Distance

This allows controlled execution of the release motion depending on the condition.


6. Key Logic Summary

  • No Unlock Signal → Start Timer
  • Timer Overrun → Alarm 발생
  • Alarm Reset 후 Mold Open 수행 → 자동 해제

7. Notes

  • Function is intended for abnormal stopper conditions
  • Improper parameter setting may lead to insufficient release or mechanical stress
  • Use conservative values during initial setup