ACOPOS Errror Text

ACOPOS Error List

ACOPOS Error List

65535: Response error

1: Invalid parameter ID

2: Data block for upload is not available

3: Write access for a read-only parameter

4: Read access for a write-only parameter

8: Data block read access already initialized

9: Data block write access already initialized

10: Data block read access not initialized

11: Data block write access not initialized

16: The data segment is already the last when reading the data block

17: The data segment is already the last when writing the data block

18: The data segment is not yet the last when reading the data block

19: The data segment is not yet the last when writing the data block

21: Checksum after data block write is invalid

23: Parameter ID in data block is invalid (data block write)

25: Burn system module only allowed immediately after download

27: Operating system not able to be started (operating system is not on the FPROM)

40: Value of parameter higher than maximum value

41: Value of parameter higher than maximum value

42: Value of parameter higher than maximum value

52: Value of parameter lower than minimum value

53: Value of parameter lower than minimum value

54: Value of parameter lower than minimum value

64: Hardware ID in BR module is invalid (data block write)

65: Hardware version in BR module is invalid (data block write)

66: The operating system on the drive is incompatible to the existing network

67: Necessary parameter is missing or is invalid

68: Data block length invalid

69: Command interface is occupied

70: Value of a necessary parameter too high

71: Value of a necessary parameter too low

72: firmware version less than minimal necessary firmware version

73: Invalid R4 floating point format

74: Parameter can only be written via channel 1 (Axis 1)

75: Parameter is not allowed for selected motor type

1001: Error-FIFO overflow

1002: Parameter outside the valid range

1003: Parameter cannot be written while loop control is active

1004: Timeout in network life sign monitor

1005: Parameter cannot be written while a movement is active

1006: Invalid parameter for trigger event (digital input + edge)

1008: Master for network coupling deactivated – Encoder error

1009: Error during memory allocation

1011: Quickstop input active

1012: Breakdown of cyclic network communication

1013: Station is not available for network communication

1014: Network command interface is occupied

1016: Maximum cycle time exceeded – CPU load too high

1017: Invalid parameter ID for cyclic read access

1018: Invalid parameter ID for cyclic write access

1021: Parameter cannot be written: Function block active

1022: Timeout in life sign monitoring of cyclic data to drive

1023: Network coupling with the cyclic communication mode not allowed

1024: Cyclic communication mode with current network configuration not possible

1025: Value of parameter in connection with holding brake not allowed

1026: Value of parameter in connection with SAFETY modules not allowed

1027: Function is not available for this hardware

1028: Maximum number of network couplings exceeded

1029: Parameter cannot be written: Stop ramp active

1030: Function is available with ACOPOS simulation only in mode ‘Complete’

1031: Position controller cycle time exceeded – CPU load too high

1032: Internal bus error

1034: Value of parameter in connection with motor encoder gear not allowed

1035: Parameter cannot be written while a encoder is active.

2001: Upload of trace data not allowed: Recording active

2003: Trace start not allowed: Recording active

2006: Initialization of trace parameters not allowed: Recording active

4005: Controller cannot be switched on: Drive in error state

4007: Lag error stop limit exceeded

4008: Positive limit switch reached

4009: Negative limit switch reached

4010: Controller cannot be switched on: Both limit switches are closed

4011: Controller cannot be switched off: Movement active

4012: Controller cannot be switched on: Init parameters missing or not valid

4014: Two encoder control: Stop limit of positions difference exceeded

4015: Error triggered by command

4016: Taskclass cycle time invalid

4017: Network cycle time invalid

5001: Target position exceeds positive SW limit

5002: Target position exceeds negative SW limit

5003: Positive SW limit reached

5004: Negative SW limit reached

5005: Start of movement not possible: Position controller inactive

5006: Start of movement not possible: Axis not referenced

5010: Move in pos. direction not possible: Pos. limit switch is closed

5011: Move in neg. direction not possible: Neg. limit switch is closed

5012: Start of movement not possible: Stop ramp active

5015: Start of movement not possible: Homing procedure active

5016: Parameter cannot be written: Homing procedure active

5017: Homing procedure mode not possible: Position controller inactive

5018: Homing procedure not possible: Movement active

5019: Homing parameter outside the valid range

5020: Homing procedure not possible: Both limit switches are closed

5021: Limit switch closed: No direction change for this homing mode

5022: Second limit switch signal received: Reference switch not found

5023: Incorrect limit switch signal received for current movement direction

5025: Homing offset with counting range correction cannot be set

5026: Basis movement parameters (with override) exceed speed limit value

5027: Basis movement parameters (with override) exceed acceleration limit value

5028: Current movement is not a basis movement

5029: Trigger ignored – remaining distance exceeds SW limit

5032: Acceleration too low – braking distance exceeds positive SW limit

5033: Acceleration too low – braking distance exceeds negative SW limit

5034: Homing procedure not possible: Encoder error

5035: Reference marks not detected

5036: Acceleration stop limit exceeded

5037: Homing procedure mode not possible: Wrong encoder type

5038: Homing procedure mode not possible: Restore data invalid

5039: Function not possible: Encoder error

5043: Homing procedure mode not possible: Compensation active

5044: Homing procedure mode not possible: Change of direction required

5101: Compensation gear: Limit values exceeded

5102: Too many changes of cam per cycle (master period too short)

5107: Cam coupling cannot be started: Parameter outside the valid range

5110: Cam coupling aborted: Cyclic set positions missing

5111: Cam coupling aborted: Encoder error

5115: Restart command not possible: The cam automat is not active

5202: Cam Control: Switch positions not in ascending order

5300: Data block for upload is not available

5301: Start cam automat linkage not possible: Parameter outside the valid range

5302: Parameter cannot be written: Cam automat active

5303: Cam data not available at index

5304: Format error in cam data

5311: Cam automat: Event leads to non initialized state

5315: Download error: Cam data in use by cam automat or function block

5316: Event type is not possible for entry in compensation gears

5319: Cam data not allowed for state 0

5329: No valid cam data

6000: Master sampling time is not a multiple of position controller sampling time

6002: Sync controller: Error tolerance of system time difference exceeded

6008: Controller is already active

6014: Drive initialization active

6017: Software: Watchdog active

6018: Hardware: Internal power supply failure

6019: ACOPOS: Overcurrent

6020: Control supply: Undervoltage

6021: Low level at controller enable input

6023: Voltage sag at controller enable input

6026: Holding brake: Stator current limit exceeded during release

6027: Holding brake: Manual operation not permitted

6029: Holding brake: Control signal on and output status off

6030: Holding brake: Brake output is active, but no brake entered in motor data

6031: System module already deleted

6032: Interface: FPGA configuration error

6033: Type of servo amplifier is not supported by ACOPOS-firmware

6034: Cyclic set value mode aborted: Set speeds missing

6036: Motor parameters missing or invalid

6038: Torque limit higher than peak motor torque

6043: PHASING_MODE is not valid

6044: Phasing: Rotational direction or position not valid

6045: Inverter: Output: No current flow

6046: Phasing: No rotor movement

6047: Holding brake: Control signal off and output status on

6048: Motor holding brake movement monitor: Position error too large

6049: Inverter: Output: Current measurement faulty

6050: Write parameter not allowed: Set current filter or notch filter active

6051: Phasing: Speed to high

6052: Power stage: High-side: Overcurrent

6053: Power stage: Low-side: Overcurrent

6054: Power stage: Overcurrent

6055: Holding brake: Low voltage

6056: Holding brake: Low current

6057: Position loop controller: Load encoder error

6058: Enable1: Voltage sag

6059: Enable2: Voltage sag

6060: Power stage: Limit speed exceeded

6061: CTRL Speed controller: Speed stop limit exceeded

6062: CTRL Speed controller: Speed error stop limit exceeded

6063: Holding brake: External voltage on output over 24V

6064: Parameter cannot be written: Repetitive Control active

6065: Initialization active

6066: Index overflow while initilization of matrices

6067: Error during initialization of the dynamical system

6068: Parameter cannot be written while a brake test is active

6069: Holding brake: Overcurrent

6070: Parameter cannot be written: Phasing procedure active

6071: Phasing: Number of polepairs MOTOR_POLEPAIRS not valid

6072: Holding brake: High voltage

6073: Additional control function in error state

6074: Control supply: Overvoltage

6075: Initialization of load simulation failed

6076: Inverter: Wiring: Phase sequence not correct

6077: Torque limit higher than maximum input torque of the motor gearbox

6078: Inverter: Summation current: Analog monitoring: Overcurrent

7000: Encoder: Error active

7012: Encoder: Hiperface error bit

7013: Encoder: Status message

7014: Encoder: CRC error during parameter transfer

7015: Encoder: Timeout error during data transmission

7017: Encoder: Error while reading encoder parameter

7022: Encoder: Initialization is active

7023: Encoder: Parameter transfer is active

7029: Encoder: Incremental signal amplitude too small

7030: Encoder: Incremental signal amplitude too large

7031: Encoder: Incremental signal amplitude too large (Disturbance)

7032: Encoder: Incremental signal amplitude too small (Disturbance, no connection)

7033: Encoder: Incremental position step too large

7036: Encoder: Interface ID invalid (Check slot and Interface EEPROM data)

7038: Encoder: Position value not synchronous with absolute value

7039: Incremental encoder: Cable disturbance track A

7040: Incremental encoder: Cable disturbance track B

7041: Incremental encoder: Cable disturbance track R

7042: Incremental encoder: Edge distance of quadrature signal too small

7043: Encoder: Cable disturbance track D

7044: Encoder: Parity

7045: Resolver: Signal disturbance (plausibility check)

7046: Resolver: Cable disturbance

7047: Invalid distance of reference marks

7048: Error during the reading of encoder memory

7049: Abnormal encoder current consumption

7050: Incremental encoder: Illegal AB signal change

7051: Encoder: Acceleration too large (Disturbance)

7052: Encoder: Encoder is not Supported

7053: Encoder: Power supply faulty

7054: Encoder: Position in channel already defined

7055: Encoder: Invalid content type ‘frame end’

7057: Encoder: Register read/write forbidden or not implemented

7058: Encoder: Alarm bit is set

7059: Virtual Encoder: Error state

7060: Virtual Encoder: Transition error

7061: Virtual Encoder: stall detection

7062: Encoder: SafeMOTION module not ready

7063: Encoder: Error in the UART communication

7064: Encoder: Error in the SafeMOTION communication

7065: Encoder: Encod type invalid

7066: Encoder: Encoder not ready

7067: Encoder: SafeMOTION modul not in operational state

7068: Encoder: Maximum cycle time exceeded

7069: Encoder: encoder error filter activ

7070: Encoder: Lag error stop limit exceeded

7071: Encoder: Limit speed error exceeded

7072: Encoder: Transfer time position exceeded

7073: Encoder: Multiturn failure

7074: Encoder: SafeMOTION error

7075: Encoder: Incorrect configuration encoder type

7076: Encoder: Data transfer active

7077: Encoder: Encoder evaluation blocked by the SafeMOTION configuration

7078: Encoder: Inter-segment communication failed

7079: Encoder: Internal error

7080: Encoder: Error in the encoder communication

7081: Encoder: Timeout during initialization

7082: Encoder: Link to encoder disturbed

7083: Reference pulse monitoring: Faulty position, resolution, or reference pulse

7084: Encoder: Error in the position evaluation

7085: Encoder: SafeMOTION not initialized

7087: Encoder Emulation: Network connection interrupted

7089: Encoder: HIPERFACE DSL: Online status: Bit 2: QMLW: Quality monitor. Low-level

7090: Encoder: HIPERFACE DSL: Online status: Bit 3: FIX0: Bit not ‘0’

7091: Encoder: HIPERFACE DSL: Online status: Bit 8: PRST: Protocol reset

7092: Encoder: HIPERFACE DSL: Online status: Bit 9: DTE: Deviation Threshold Error

7093: Encoder: HIPERFACE DSL: Online status: Bit 12: FIX1: Bit not ‘1’

7094: Encoder: HIPERFACE DSL: Online status: Bit 14: SUM: Summary byte enc. status

7095: Encoder: Encoder type not supported by SafeMOTION firmware

7100: Parameter function is not supported.

7103: Incompatible interface

7104: Initialization aborted

7200: DC bus: Overvoltage

7210: DC bus: Pre-charging: Voltage unstable

7211: DC bus: Voltage dip

7212: DC bus: Large voltage dip

7214: DC bus: Pre-charging resistor hot (too many power line fails)

7215: Power mains: At least one phase of the power line failed

7217: DC bus: Nominal voltage detection: Voltage too high

7218: DC bus: Nominal voltage detection: Voltage too low

7219: DC bus: Pre-charging: Voltage too low

7220: DC bus: Nominal voltage detection: Voltage not allowed

7221: Mains: Failure

7222: Inverter: Summation current: Overcurrent

7223: DC bus: Overvoltage DC-GND

7224: Connector to back plane: 24V-GND contact monitoring: Voltage too low

7225: DC bus: Overvoltage

7226: DC bus: Overcurrent

7227: Bleeder: Overcurrent

7228: DC bus: Nominal voltage detection: High inrush current

7229: Chopper: Overcurrent

7230: DC bus: center voltage limit exceeded

7231: Motor: Overvoltage

7232: Mains: Detected frequency outside the range [20,200]

7300: Analog/Digital IO: IO Configuration invalid

7303: Analog/Digital IO: 24V power supply fail

7304: Analog/Digital IO: Network connection interrupted

7305: Digital IO: Digital output: Diagnose bit active

7306: Analog IO: Analog output: Diagnose bit active

7401: Parameter position exceeds maximum data length

7402: Processing of parameter sequence aborted: Write error

7403: Processing of parameter sequence is still active

7404: Parameter sequence not available at index

8001: EEPROM select not valid

8003: Table index not valid

8004: EEPROM variable type not valid

8005: EEPROM type not valid

8006: Value of EEPROM parameter is zero

8007: Value of EEPROM parameter is not valid

8011: EPROM: Data not valid

8012: EPROM: Controller-ID not valid

8013: EPROM: CRC error

8020: Invalid switch frequency

8021: User decice configuration data: CRC error

8022: User decice configuration data: Parameter value invalid

9000: Heatsink temperature sensor: Stop limit exceeded

9001: Heatsink temperature sensor: Switch off limit exceeded

9003: Heatsink temperature sensor: Not connected or destroyed

9010: Temperature sensor (Motor|Choke|External): Stop limit exceeded

9011: Temperature sensor (Motor|Choke|External): Switch off limit exceeded

9012: Temperature sensor (Motor|Choke|External): Not connected or destroyed

9013: Temperature sensor (Motor|Choke|External): Short circuit

9030: Junction temperature model: Stop limit exceeded

9031: Junction temperature model: Switch off limit exceeded

9040: Bleeder temperature model: Stop limit exceeded

9041: Bleeder temperature model: Switch off limit exceeded

9050: ACOPOS peak current: Stop limit exceeded

9051: ACOPOS peak current: Switch off limit exceeded

9060: ACOPOS continuous current: Stop limit exceeded

9061: ACOPOS continuous current: Switch off limit exceeded

9070: Motor temperature model: Stop limit exceeded

9071: Motor temperature model: Switch off limit exceeded

9075: ACOPOS continuous power: Stop limit exceeded

9076: ACOPOS continuous power: Switch off limit exceeded

9078: Power stage: Temperature sensor 1: Stop limit exceeded

9079: Power stage: Temperature sensor 1: Switch off limit exceeded

9080: Pre-charging resistor temperature model: Stop limit exceeded

9081: Power stage temperature model: Stop limit exceeded

9082: Power stage temperature model: Switch off limit exceeded

9083: Power stage: Temperature sensor 2: Stop limit exceeded

9084: Power stage: Temperature sensor 2: Switch off limit exceeded

9085: Power stage: Temperature sensor 3: Stop limit exceeded

9086: Power stage: Temperature sensor 3: Switch off limit exceeded

9087: Power stage: Temperature sensor 4: Stop limit exceeded

9088: Power stage: Temperature sensor 4: Switch off limit exceeded

9089: Encoder temperature sensor: Stop limit exceeded

9090: Encoder temperature sensor: Temperature value not valid

9091: 24V Supply/Main relay temperature sensor: Stop limit exceeded

9092: Power stage: Temperature sensor 5: Stop limit exceeded

9093: Power stage: Temperature sensor 5: Switch off limit exceeded

9094: Rectifier temperature model: Stop limit exceeded

9095: Rectifier temperature model: Switch off limit exceeded

9096: DC bus relay temperature model: Stop limit exceeded

9097: DC bus relay temperature model: Switch off limit exceeded

9098: DC bus capacitor temperature model: Stop limit exceeded

9099: DC bus capacitor temperature model: Switch off limit exceeded

9100: DC bus: Continuous total power: Stop limit exceeded

9101: DC bus: Continuous total power: Switch off limit exceeded

9102: DC bus: Peak total power: Stop limit exceeded

9103: DC bus: Peak total power: Switch off limit exceeded

9104: DC connector temperature model: Stop limit exceeded

9105: DC connector temperature model: Switch off limit exceeded

9106: Power stage: Temperature sensor: Stop limit exceeded

9107: Power stage: Temperature sensor: Switch off limit exceeded

9108: Motor: Temperature sensor: Multiplexer reference voltage fail

9110: Motor temperature model: Stop limit exceeded

9111: Motor temperature model: Switch off limit exceeded

9300: Current controller: Overcurrent

9302: Current controller: Cycle time invalid

9303: Infeed: Summation current: Overcurrent

10000: Identification parameter(s) missing

10001: Parameter identification: Invalid sub-mode

10100: Parameter identification: Quality factor not fulfilled

10101: No ISQ-filter free

10102: No resonance-frequency for ISQ-filter (band-stop) found

10103: Autotuning: Maximum lag error exceeded

10104: Parameter identification: Movement during identification of the position

10105: Parameter identification: Plausibility check of the shuttle positions

10500: Induction stop was terminated

11000: Inter segment communication: Wiring fault

11101: Encoder: Signal amplitude too low

11102: Encoder: Signal amplitude too high

31201: Di/Do Interface: Drive not ready

31220: Encoder error: Encoder not configured

31221: Encoder error: Cable disturbance or signal disturbance

31224: Encoder Interface: HW Module not OK

31240: Homing procedure mode not allowed with current HW Type

31247: Drive Interface: DrvOK not set from HW Module

31248: Trigger Interface: HW Module not OK

31249: Drive Interface: HW Module not OK

31250: Di/Do Interface: HW Module not OK

31260: Current axis configuration only possible in simulation mode

31261: Change mode for servo drive adjustment not allowed

32001: Error calling CAN_xopen()

32002: Error defining Write COB for Broadcast Command

32003: Error defining Write COB for Parameter Read Request

32004: Error defining Write COB for Parameter Write Request

32005: Error defining Read COB for Parameter Read Response

32006: Error defining Read COB for Parameter Write Response

32007: Error defining Read COB for Monitor Data from the drive

32008: Error sending Read Request (network error ?)

32009: Error sending Write Request (network error ?)

32010: Drive not responding to Read Request (is the drive in the network ?)

32011: Drive not responding to Write Request (is the drive in the network ?)

32012: Error reading module description of system module

32013: No operating system present on the drive

32014: NCSYS version on the drive not compatible with NC software version

32015: Error creating message queue

32016: Error sending an idle time command to the NC Manager Task

32017: Wrong boot state after start of operating system

32018: Invalid Parameter ID in system module

32019: Download of NC system module not allowed (the module is on the PLC)

32020: System module data could not be read from the drive for initialization

32021: System module data could not be read from the drive after download

32022: Error aborting data block access before download

32023: Error reading boot state before download

32025: Wrong boot state after SW Reset before download

32026: Error during INIT of data block write access for download

32027: Error sending data segment for download

32029: Response error after sending data segment for download

32030: Error at command for system module burn after download

32031: Error reading status for system module burn after download

32032: Error while burning system module after download

32033: Timeout while burning system module after download

32034: Error at SW Reset before download

32035: Error at SW Reset after download

32036: Different system module data after download

32037: Error message(s) lost because of FIFO overflow (acknowledge errors)

32040: Version of INIT parameter module is not compatible to NC manager

32041: The module acp10cfg does not exist

32042: The module acp10cfg is not an NC data module

32043: The NC module type of the module acp10cfg is invalid

32044: The NC module type of the module acp10cfg cannot be read

32045: The data address in module acp10cfg cannot be read

32046: The data section of module acp10cfg is empty

32047: A CAN node number in module acp10cfg is invalid

32048: A CAN node number in module acp10cfg is used repeatedly

32049: This NC action is not allowed during Trace is active

32050: A Trace Data Upload is already active

32053: Error defining Write COB for Parameter Read Request 2

32054: Error defining Write COB for Parameter Write Request 2

32055: Error defining Read COB for Parameter Read Response 2

32056: Error defining Read COB for Parameter Write Response 2

32057: Error accessing HS task class table

32058: Error accessing task class table

32059: Parameter tk_no invalid for access to task class table

32060: Timeout for cyclic data from drive – Indications invalid (network error ?)

32061: Timeout sending a Read Request telegram (network error ?)

32062: Timeout sending a Write Request telegram (network error ?)

32063: Data address zero (set/read parameter via service interface)

32064: Converting text into binary data is not possible for this parameter data type

32065: Converting binary data into text is not possible for this parameter data type

32066: Parameter ID zero (set/read parameter via service interface)

32067: Parameter ID invalid (converting text to/from binary data not possible)

32069: The data address of the ACOPOS parameters in module acp10cfg cannot be read

32070: Drive for ACOPOS parameters in module acp10cfg not found

32071: The ACOPOS parameters are invalid (an update of AutomationStudio is necessary)

32072: Wrong boot state after SW Reset

32073: Download of NC system module: Error reading NC hardware version of BsLoader

32074: Incompatible NC hardware version: Download of BsLoader not possible

32075: Incompatible NC hardware version: Download of operating system not possible

32076: The FIFO for messages with high priority to NC Idle Task is full

32077: A POWERLINK node number in module acp10cfg is invalid

32078: A POWERLINK node number in module acp10cfg is used repeatedly

32079: With this variant one CAN interface must be in module acp10cfg

32080: With this variant one POWERLINK interface must be in module acp10cfg

32084: The NC configuration does not contain any ACOPOS module

32085: Module acp10cfg invalid (AutomationStudio V2.2 or higher necessary)

32086: With this variant no CAN interface is allowed in module acp10cfg

32087: With this variant no POWERLINK interface is allowed in module acp10cfg

32088: The INIT parameter module specified in the NC Mapping Table does not exist

32089: NC-HW-ID of INIT parameter module is not compatible to NC manager

32090: NC object type of INIT parameter module is not equal to NC object

32091: Invalid block data in INIT parameter module (data range exceeded)

32092: Error sending a command to the NC Idle Task

32093: NcManCtrl is defined repeatedly with different values

32094: NetworkInit is defined repeatedly for ncMANAGER with different values

32095: Value of drive group in CAN-CFG-Module higher than maximum value

32098: Version of the module acp10cfg is not compatible with NC manager

32099: Length of data section of module acp10cfg is too small

32100: Memory for NC error text management cannot be allocated

32102: Version ID of error text module not equal to that of NC manager

32103: Data section of error text module cannot be read

32104: Data section of error text module is empty

32105: Length of data section of error text module is too small

32106: Error list of error text module not equal with that of NC manager

32107: Parameter list of error text module not equal with that of NC manager

32108: The last error number of error text module is not equal to 65535

32109: The last parameter ID of error text module is not equal to 65535

32110: Length of data section of CAN-CFG-Module cannot be read

32111: Length of data section of CAN-CFG-Module is too small

32112: The data address in the CAN-CFG-Module cannot be read

32113: The enable code in the CAN-CFG-Module is invalid

32114: Values not equal to zero in reserved area of CAN-CFG-Module

32115: The basis CAN ID for WR/RD channel1 in the CAN-CFG-Module is invalid

32116: The basis CAN ID for WR/RD channel2 in the CAN-CFG-Module is invalid

32117: The basis CAN ID for WR/RD channel3 in the CAN-CFG-Module is invalid

32118: The basis CAN ID for monitor data in the CAN-CFG-Module is invalid

32119: Invalid basis CAN ID for cyclic data to the drive in CAN-CFG-Module

32120: Invalid basis CAN ID for cyclic data from the drive in CAN-CFG-Module

32121: The CAN ID for the SYNC telegram in the CAN-CFG-Module is invalid

32122: The CAN ID for the broadcast command in the CAN-CFG-Module is invalid

32123: Error defining Read COB for WR2 Request (external set position mode)

32124: Error defining Read COB for WR2 Response (external set position mode)

32125: Error defining Read COB for RD2 Request (external set position mode)

32126: Error defining Read COB for RD2 Response (external set position mode)

32127: Error deleting Write COB for Broadcast Command (external set position mode)

32128: Error defining Read COB for Broadcast Command (external set position mode)

32129: Error defining Read COB for cyclic user data from drive (ext. set pos. mode)

32130: This external set position mode is only allowed with one CAN interface

32131: The specified NC data module does not exist

32132: The specified module is not an NC data module

32133: The NC module type of the specified NC data module is invalid

32134: The NC module type of the specified NC data module cannot be read

32135: The data address of the specified NC data module cannot be read

32136: The data section of the specified NC data module is empty

32137: Data address of structure for a data block operation is zero

32138: Data address zero (data structure for data block operation)

32139: Data length zero (data structure for data block operation)

32140: Data block operation: Data module name or data address must be zero

32141: Invalid data format in a parameter sequence

32142: ID or type of a parameter invalid in parameter sequence with text format

32143: Data of a parameter in a parameter sequence longer than 6 bytes

32144: Error for an ACOPOS parameter table specified in the NC Mapping Table

32145: The ACOPOS parameter table does not exist

32146: The ACOPOS parameter table is not an NC data module

32147: The NC module type of the ACOPOS parameter table is invalid

32148: The NC module type of the ACOPOS parameter table cannot be read

32149: The data address in the ACOPOS parameter table cannot be read

32150: The data section of the ACOPOS parameter table is empty

32151: Error initializing memory buffer for XML parser

32152: No XML elements present in an ACOPOS parameter table

32153: The first XML element is invalid in the ACOPOS parameter table

32154: The ACOPOS parameter table does not contain any ACOPOS parameters

32155: Nesting depth for ACOPOS parameter groups exceeded

32156: ID or type of an ACOPOS parameter invalid for text conversion

32157: Length of parameter data too large for ACOPOS parameter in XML data

32158: ACOPOS parameter: An attribute is not defined (ID)

32159: ACOPOS parameter: An attribute is not defined (Value)

32161: ncNC_SYS_RESTART,ncACKNOWLEDGE is not allowed (network.init=ncFALSE)

32163: A system module download to all drives is not possible with SwNodeSelect

32164: The text defined with NetworkInit (global) is invalid

32165: A CAN node number is equal to NodeNr_SwNodeSelect

32166: Network initialization not allowed during active network initialization

32167: The text defined with NetworkInit is invalid

32168: NodeNr_SwNodeSelect is defined repeatedly with different values

32169: The node number defined with NodeNr_SwNodeSelect is invalid

32170: A data module name has to be entered for this data block operation

32171: Index zero is not allowed (data structure for data block operation)

32172: The specified data module name is not valid for a BR module

32173: Memory for data module creation cannot be allocated

32174: Error with installation of data module into BR module table

32175: Error with installation of data module into BR module table

32176: Text for parameter data too large for parameter sequence with text format

32177: Text for parameter data too large for parameter list with text format

32178: This axis is not enabled for this ACOPOS (channel number too high)

32179: ID or type of a parameter invalid in parameter list with text format

32180: Data address of structure for a parameter list operation is zero

32181: Data address zero (data structure for parameter list operation)

32182: Data length zero (data structure for parameter list operation)

32183: Data length invalid (data structure for parameter list operation)

32184: Invalid data format in a parameter list

32185: Data of a parameter in a parameter list longer than 6 bytes

32186: NetBasisInitNr is defined repeatedly for ncMANAGER with different values

32187: Error for synchronization of network initialization (details in Logger)

32188: This NC object is defined in hardware configuration and NC Mapping Table

32189: Timeout for cyclic data from drive – Indications invalid (network error ?)

32190: Error defining Write COB for selection of node number via software

32191: This parameter ID is reserved for the PLCopen MC library

32192: The specified data module is not an INIT Parameter module

32193: For this NC object type no INIT parameter module is present

32194: This function is not implemented for this NC object type

32195: Error downloading BsLoader to ACOPOS

32196: Error downloading operating system to ACOPOS

32197: Error downloading BsLoader to ACOPOS (additional info in Logger)

32198: Error downloading operating system to ACOPOS (additional info in Logger)

32200: Error calling plAcycWrite() (read parameter)

32201: Error calling plAcycWrite() (write parameter)

32202: Error calling plAcycRead() (read parameter)

32203: Error calling plAcycRead() (write parameter)

32204: Timeout while reading par. via acyclic channel (is the drive in the network ?)

32205: Timeout while writing par. via acyclic channel (is the drive in the network ?)

32206: Cyclic channel: Read Request in spite of Wait for Response

32207: Cyclic channel: Write Request in spite of Wait for Response

32208: Error using plAction(DEVICE_TO_BUS_NR) (additional info in Logger)

32209: Error using plAction(GET_IDENT) (additional info in Logger)

32210: Wrong interface ident when calling plState() (additional info in Logger)

32211: Interface not available when calling plState() (additional info in Logger)

32212: Fatal interface error when calling plState() (additional info in Logger)

32213: Timeout for POWERLINK interface (additional info in Logger)

32214: Error calling plAcycOpen() (additional info in Logger)

32215: Error calling plCECreate() (additional info in Logger)

32216: Error using plAction(GET_IF_PAR) (additional info in Logger)

32217: Broadcast channel: Error calling plAcycWrite() (read parameter)

32218: Broadcast channel: Error calling plAcycWrite() (write parameter)

32219: Error using plAction(GET_IF_MUXPRESCALE) (additional info in Logger)

32220: Error using plAction(GET_IF_CYCLE_TIME) (additional info in Logger)

32221: Error using plAction(GET_IF_PRESCALE) (additional info in Logger)

32222: Error using plAction(GET_STATIONFLAG) (additional info in Logger)

32223: Error calling plGetNodeInfo() (additional info in Logger)

32224: Error calling plAction(GET_PROTOCOL_VERSION) (additional info in Logger)

32225: This ACOPOS POWERLINK node does not exist in the AR Configuration

32226: A SDC node number in module acp10cfg is invalid

32227: A SDC node number in module acp10cfg is used repeatedly

32228: There is no network interface (POWERLINK or SDC) contained in acp10cfg

32229: The SDC object needed for operation of SDC axes does not exist

32230: Error at initialization of SDC oder SIM object (see Logger)

32231: Error at SDC configuration (see Logger)

32232: The SIM object needed for ACOPOS Simulation does not exist

32233: NCBSL (name see logger) contains no NC system module with module type 0x4F

32234: NCSYS (name see logger) contains no NC system module with module type 0x4F

32235: Data address zero for parameter in parameter sequence

32236: Data address zero for parameter in parameter list

32237: Channel index for ACOPOS parameters in module acp10cfg is invalid

32238: This function is not implemented at this time

32239: Basic memory for INIT parameter modules could not be allocated

32240: NC object data invalid (PV with INIT value in variable declaration ?)

32241: Data block operation: Data module name must be zero

32243: Error using plAction(GET_PDO_INFO) (additional info in Logger)

32244: No PDO defined in the cyclic frame for this channel: The channel is disabled

32245: The Memory for operating the broadcast channel cannot be allocated

32246: ‘Direction’ of the POWERLINK broadcast channel is not ‘Output’

32247: Error using plAction(GET_TC_INFO) (additional info in Logger)

32248: Invalid ACOPOS parameter header in module acp10cfg (section exceeded)

32249: Invalid ACOPOS parameter descriptor in module acp10cfg (section exceeded)

32250: ACOPOS parameter in module acp10cfg: Length of parameter data too large

32251: NcNetCyc: Response timeout

32252: NcNetCyc: Unexpected Response (invalid counter value)

32253: The task class for POWERLINK output cycle trigger is invalid

32254: No PDO mapping defined (PDO mapping is required for this ACOPOS ID)

32255: Trace start is not allowed while trace is active

32256: Trace trigger: Invalid Data

32257: Trace trigger: This channel is not enabled for this ACOPOS

32258: More than one trace trigger defined for a channel

32259: There are currently no trace data to be saved

32260: Trace: No valid test data point is defined

32261: Trace trigger: Invalid data

32262: Trace test data point: Invalid data

32263: Trace trigger: This channel is not enabled for this ACOPOS

32264: Trace test data point: This channel is not enabled for this ACOPOS

32265: Trace trigger: Trace for this NC object already active at trace start

32266: Trace test data point: Trace for this NC object already active at trace start

32267: Trace trigger: The NC object is not enabled for trace commands

32268: Trace test data point: The NC object is not enabled for trace commands

32269: Trace: Too many test data points defined for one trace channel

32270: ACOPOS coupling: The channel number of the send data is invalid

32271: ACOPOS coupling: The channel number of the receive data is invalid

32272: ACOPOS coupling: Send data with this channel number are not configured

32273: ACOPOS coupling: The NC object of the send data is invalid

32274: Network coupling: The broadcast channel was not configured

32275: Network coupling: The broadcast channel was not successfully initialized

32276: Network coupling: Cycle times not equal (POWERLINK, NC task class)

32277: Network coupling: In the broadcast channel no more data record has place

32278: ACOPOS coupling: Zero as Parameter ID of the send data is not allowed

32279: Service interface: Data address zero

32280: Timeout for enable of acyclic network communication

32281: Version of SafeMC lower than minimum version (see Logger)

32282: Network coupling: Incompatible cycle times (POWERLINK, NC task class)

32283: INIT broadcast data point: Call of action only allowed with NC task class

32284: Ext. coupling data: With this AR/NC version only for TC1 with synchr. output

32285: INIT broadcast data point: Incompatible cycle times (POWERLINK, NC task class)

32286: Network coupling: Incompatible cycle times (network interfaces, NC task class)

32287: Extended coupling data not possible (OutTime difference too large)

32288: Extended coupling data not possible (task class tolerance is not zero)

32289: Network coupling: SDC/SIM master and slave in different task classes

32290: INIT broadcast data point: Call of NC action only allowed in SDC task class

32291: INIT broadcast data point:

32292: Data of a parameter in a parameter list longer than 8 bytes

32302: Start setup not possible: A setup operation is already active

32322: Data block upload/download: The data object name is zero

32323: Data block upload/download: The data block parameter ID is invalid

32324: Data block upload/download: The parameter ID of data block index 1 is invalid

32325: Data block upload/download: The parameter ID of data block index 2 is invalid

32326: Data block upload/download: Address of data buffer is zero

32327: Data block upload/download: Length of data buffer is zero

32328: Data block upload: Length of data buffer lower than length of data block

32329: Setup: Maximum number of initial ACOPOS parameters exceeded

32330: Setup: Data of an ACOPOS parameter longer than 6 bytes

32331: Start setup not possible: The mode parameter is zero

32392: Network coupling: Incompatible cycle times (POWERLINK, NC task class)

32393: Network coupling: Incompatible cycle times (POWERLINK, NC task class)

32394: INIT broadcast data point: Incompatible cycle times (POWERLINK, NC task class)

32395: Ext. coupling data: Only possible with synchr. output for task class Cyclic #1

32396: Changing the cycle time is not allowed for this ACOPOS hardware type

32397: NCSYS version on the target system is not compatible with NC software version

32398: NCSYS does not contain an operating system for this ACOPOS hardware type

32399: Manual ACOPOS restart (POWER-OFF/-ON) after NCSYS download necessary

32400: Memory cannot be allocated

32401: No data object name specified

32402: The specified file cannot be opened

32403: The specified file cannot be created

32404: Error at writing into a file

32405: Error at reading from a file

32406: The specified file cannot be created

32407: Error at writing into a file

32408: Error at closing a file

32409: The specified file cannot be deleted

32410: The data object type is invalid

32411: The address of the data object structure is zero

32412: The name in the data object structure is zero

32413: The data address in the data object structure is zero

32414: The data length in the data object structure is zero

32415: No File Device specified

32416: The FileIO functions do not exist (is library FileIO existing ?)

32417: Error at writing into an NC data module

32418: No XML elements present in MTC data

32419: MTC data: XML elements invalid or in wrong order

32420: The MTC data contain an invalid configuration

32421: The MTC data contain no configuration for Multi Axes Trace

32422: The MTC data contain more than one configuration for Multi Axes Trace

32423: MTC data: Trigger.NcObject is invalid

32424: MTC data: Trigger.Condition is invalid

32425: MTC data: Channel.NcObject is invalid

32426: Trace trigger: The event is invalid

32427: Trace trigger: Parameter ID zero not allowed if event unequal to OFF

32428: The data object format is invalid

32429: MTC data: Maximum number of test data points exceeded

32430: Data could not be read from NCBSL module (name see logger)

32431: Data could not be read from NCSYS module (name see logger)

32432: Trace not possible: The ACOPOS startup is not yet complete

32492: ACOPOS Simulation: TC for cyclic PLCopen data not equal to NC Manager TC

32494: AcoposSimulation=Off for one channel although activated for the other channel

32495: AcoposSimulation: Different values defined for real and virtual axis

32496: Error creating cyclic task for PLCopen MC (details in Logger)

32497: Task class for handling of cyclic data with PLCopen in acp10cfg is invalid

32498: PLCopen_CyclicData_TaskClass is lower than zero or higher than maximum value

32499: PLCopen_CyclicData_TaskClass: Values for real and virtual axis are not equal

32500: The Message FIFO already exists

32501: Error creating Message FIFO

32502: The Critical Section for Command Semaphore already exists

32503: Error creating Critical Section for Command Semaphore

32504: The NC Idle Task already exists

32505: Error creating NC Idle Task

32506: Error reading Taskclass Cycle Time

32507: Error reading Taskclass Tolerance

32508: Error sending an idle time command to the NC Idle Task

32509: The Critical Section for Network Command Trace already exists

32510: Error creating Critical Section for Network Command Trace

32511: The Critical Section for messages with high priority already exists

32512: Error creating Critical Section for messages with high priority

32513: The Critical Section for global variables already exists

32514: Error creating Critical Section for global variables

32515: The Critical Section for network coupling already exists

32516: Error creating Critical Section for network coupling

32738: Error writing into SDM Motion FIFO

32739: Error creating SDM Motion FIFO (see Logger)

32740: Error deleting SDM Motion FIFO (see Logger)

32741: Error creating SDM Motion task (see Logger)

32742: Error deleting SDM Motion task (see Logger)

32743: SDM_Motion_Action: ncaction() did not return with ncOK

32744: SDM_Motion_Action not allowed (still no Trace configuration loaded)

32745: SDM_Motion_Action not allowed (Motion Trace already started by application)

32746: SDM_Motion_Action not allowed (Motion Trace already started by SDM)

32747: SDM_Motion_Action: DataAddress is zero or defined

32748: SDM_Motion_Action: DataLen is zero or defined

32749: SDM_Motion_Action: BrModName is too long

32750: SDM_Motion_Action: BrModName is not defined

32751: SDM_Motion_Action: FileName is not defined

32752: SDM_Motion Action not possible: AR function does not exist (see Logger)

32753: SDM_Motion_Action: CREATE_NCOBJ_LIST must be called before this action

32754: SDM_Motion_Action: The NC object type is invalid for this action

32755: SDM_Motion_Action: Memory free error

32756: SDM_Motion_Action: Memory alloc error

32757: SDM_Motion_Action: This action is not yet implemented

32758: SDM_Motion_Action: The NC object ident is invalid for this action

32759: SDM_Motion_Action: The NC object ident must be zero for this action

32760: SDM_Motion_Action: Pointer of exit function arguments is zero or not defined

32761: SDM_Motion_Action: Pointer of exit function is zero or not defined

32762: SDM_Motion_Action: The first XML element in input data is invalid

32763: SDM_Motion_Action: No XML element in input data

32764: SDM_Motion_Action: Error initializing memory buffer for XML parser

32765: SDM_Motion_Action: Length of XML input data is zero

32766: SDM_Motion_Action: Pointer of XML input data is zero

32767: SDM_Motion_Action: Invalid actionID

33002: Floating-Point exception

33003: Address error exception

33004: Bus error exception

33005: Exception

33006: Access violation Exception

33007: Violation address

35000: SMC FS: Internal error, Program flow

35001: SMC FS: Internal error, NULL pointer access

35002: SMC FS: Internal error, SPI transfer

35003: SMC FS: Internal error, MFW NVM data memory

35004: SMC FS: Internal error, Communication Encoder Master

35005: SMC FS: Internal error, Communication ACOPOS

35006: SMC FS: Internal error, Communication Encoder

35007: SMC FS: Module/compensation data is incompatible!

35008: SMC FS: CRC of the module/compensation data is not correct!

35009: SMC FS: SOS and STO not connected but needed for RSP

35010: SMC FS: Internal error, Axis index out of range

35011: SMC FS: Internal error, Function parameter out of range

35012: SMC FS: Unsafe encoder connected

35013: SMC FS: ACP10 version does not support the enabled safety function

35014: SMC FS: Function is not supported by hardware.

35015: SMC FS: Internal error, Cross communication cycle f5

35016: SMC FS: Internal error, Cross communication of checkpoints

35017: SMC FS: Internal error, Cross communication of status word

35018: SMC FS: Internal error, Cross communication of output state

35019: SMC FS: Internal error, Cross communication of EnDat position

35020: SMC FS: Internal error, Cross communication of EnDat error register

35021: SMC FS: Internal error, Cross communication of Encoder state machine

35022: SMC FS: Internal error, Cross communication of EnDat state machine

35023: SMC FS: Internal error, Cross communication of EnDat state machine

35024: SMC FS:

35025: SMC FS:

35026: SMC FS: EUS – Encoder resolution too low

35027: SMC FS: EUS – Encoder resolution too high

35028: SMC FS: EUS – Units resolution too high

35029: SMC FS: EUS – One unit is shorter than one nm

35030: SMC FS: Encoder mismatch – Configuration data changed several times

35031: SMC FS: Encoder mismatch – Configuration data changed

35032: SMC FS: Wrong parameterization

35033: SMC FS: Module cycle time is not valid

35034: SMC FS: Parameterization – Deceleration ramp is too steep

35035: SMC FS: Internal state machine is in Fail Safe State

35036: SMC FS: Deactivated safety function was requested

35037: SMC FS: SMS – Speed limit is out of range

35038: SMC FS: SLS1 – Speed limit is out of range

35039: SMC FS: SLS2 – Speed limit is out of range

35040: SMC FS: SLS3 – Speed limit is out of range

35041: SMC FS: SLS4 – Speed limit is out of range

35042: SMC FS: Standstill speed limit is out of range

35043: SMC FS: SLS1 – Speed limit violates the configuration instruction

35044: SMC FS: SLS2 – Speed limit violates the configuration instruction

35045: SMC FS: SLS3 – Speed limit violates the configuration instruction

35046: SMC FS: SLS4 – Speed limit violates the configuration instruction

35047: SMC FS: Standstill Speed limit violates the configuration instruction

35048: SMC FS: Violation of parameter limits

35049: SMC FS: SMP is used but Homing was not configured

35050: SMC FS: SMP – Lower position limit is greater or equal than upper limit

35051: SMC FS: SLP is used but Homing was not configured

35052: SMC FS: SLP – Lower position limit is greater or equal than upper limit

35053: SMC FS: SLP – Position window outside SMP position window

35054: SMC FS: SMP – Tolerance is greater than SMP position window

35055: SMC FS: SLP – Tolerance is greater than SLP position window

35056: SMC FS: Value of Deceleration ramp is out of range

35057: SMC FS: SLT Parameterization – Torque limit too high

35058: SMC FS: Motor Parameterization – Torque characteristic invalid

35059: SMC FS: BM Parameterization – Configured SF invalid

35060: SMC FS: SSO tolerance violates the configuration instruction

35061: SMC FS: SMS – Speed limit violates the configuration instruction

35062: SMC FS: SMS – Speed lag error monitoring not activated

35063: SMC FS: SMS – Position lag error monitoring activated

35064: SMC FS: SMS – Homing activated

35065: SMC FS: SMS – A not allowed safety function is activated

35066: SMC FS: SMS – Access SwitchHomingMode activated

35067: SMC FS: Internal error, Cross communication cycle f2

35068: SMC FS:

35069: SMC FS: Homing – Ref Switch: No reference switch connected

35070: SMC FS: Homing – Home Offset: No absolute encoder connected

35071: SMC FS: Homing – Home Offset with Correction: SMP not configured

35072: SMC FS: Homing – SMP window is greater than safe absolute encoder range

35073: SMC FS: Homing – SLP window is greater than safe absolute encoder range

35074: SMC FS: Homing – Encoder doesn’t support a safe reference pulse

35075: SMC FS: Homing – Speed tolerance is out of range

35076: SMC FS: Homing – reference pulse : Max. trigger speed is too big

35077: SMC FS: Homing – Function is requested but not configured

35078: SMC FS: Homing – RefSwitch bit is set but not configured

35079: SMC FS: Homing – Position is out of SMP window

35080: SMC FS: Homing – Direct with reference pulse: Not supported

35081: SMC FS: Internal error, Cross communication of output signals

35082: SMC FS: Internal error, Cross communication of output state machine

35083: SMC FS: Internal error, Cross communication preop f2

35084: SMC FS: Program error in PreOperational state

35085: SMC FS: Safe output – Stuck at high detected

35086: SMC FS: Safe output – Test state has changed

35087: SMC FS: Encoder – Speed limit exceeded

35088: SMC FS: Encoder – Acceleration limit exceeded

35091: SMC FS: Encoder mismatch detected

35092: SMC FS: Internal error, Lockbit set

35093: SMC FS: Velocity error tolerance too large

35094: SMC FS: Lag error tolerance too large

35095: SMC FS: Encoder – Configuration error

35096: SMC FS: Homing – Configuration error

35097: SMC FS: Internal error, Invalid current sensor resolution

35098: SMC FS: Internal error, Invalid current sensor measurement range

35099: SMC FS: Internal error, Current values sum not plausible

35100: SMC FS: Internal error, Cross communication of stator current vector

35101: SMC FS: Internal error, Cross communication of current vector angle

35102: SMC FS: Internal error, Cross communication of the status register IPWM

35103: SMC FS: Internal error, Cross communication FPGACom state machine

35104: SMC FS: Internal error, FPGA communication

35105: SMC FS: Internal error, FPGA SinCos – Reference voltage Channel A

35106: SMC FS: Internal error, FPGA SinCos – Reference voltage Channel B

35107: SMC FS: Internal error, FPGA SinCos – Configuration

35108: SMC FS: Internal error, Hardware tests – Voltage monitoring

35109: SMC FS: Internal error, ADC compensation data – Flash validation

35110: SMC FS: Internal error, FPGA current measurement – ADC processing

35111: SMC FS: Internal error, FPGA current measurement – Reference monitoring

35112: SMC FS: Internal error, FPGA current measurement – Efficiency test

35113: SMC FS: Internal error, FPGA current measurement – Configuration

35114: SMC FS: Internal error, FPGA SinCos – Efficiency test

35115: SMC FS: SBT Parameterization – Current threshold too high

35116: SMC FS: SBT Parameterization – External load greater than threshold

35117: SMC FS: SBT Parameterization – External load too small

35118: SMC FS: Internal error, extended flashdata is wrong

35119: SMC FS: SBT Parameterization – External load too high

35120: SMC FS: Homing – S_SwitchHomingMode is set but not connected

35121: SMC FS: Homing – S_SwitchHomingMode is connected but ReqHoming not

35122: SMC FS: Homing – S_SwitchHomingMode connection and configuration not conform

35123: SMC FS: Internal error, Cross communication of RSP receive data frame

35124: SMC FS: Internal error, Cross communication of RSP send data frame

35125: SMC FS: RSP – Save operation failed

35126: SMC FS: RSP – Homing, SOS position tolerance too big

35127: SMC FS: Internal error, Invalid current sensor measurement offset

35128: SMC FS: Internal error, Sigma delta conversion is not plausible

35129: SMC FS: Internal error, gain and offset corrected current out of range

35130: SMC FS: Internal error, testcase

35131: SMC FS: Internal error

35132: SMC FS: BM – Delay time to FFS is larger 0.8 * Node Guarding Timeout

35133: SMC FS: SMS – Safe maximum speed (SMS) in combination with SSO not allowed

35134: SMC FS: SMS – Safe stop 1 (SS1) with ramp monitoring not allowed

35135: SMC FS: SMS – Safe stop 1 (SS1) with early limit monitoring not allowed

35136: SMC FS: Safe Encoder mounting error

35137: SMC FS: SafeUserData – Configuration error in function SafeUserData

35138: SMC FS: HDSL – Error in HIPERFACE DSL configuration

35139: SMC FS: HDSL – Error in Encoder protocol type configuration

35140: SMC FS: HDSL – Internal communication error

35150: SMC FS: Additional safety parameters: Disbld. function enable bit is set

35151: SMC FS: Additional safety parameters: Placeholder enable bit is set

35152: SMC FS: Additional safety parameters: Invalid payload size

35153: SMC: Interner error, CUnit test

35154: SMC FS: Additional safety parameters: Invalid structure size

35155: SMC FS: Received data for additional safety parameters too big

35156: SMC FS: CRC chekc of the additional safety parameters failed

35161: SMC FS: Incompatible parameter structure

35162: SMC FS: Incompatible axis type

35163: SMC FS: Error in PreOperational function

35164: SMC FS: Cross communication SinCos status during FPGA boot phase

35165: SMC FS: Encoder not configured but needed for safety functions

35166: SMC FS: Squared vector length too large

35167: SMC FS: Cross communication vector control trigger counter

35170: SMC FS: SBT Current threshold too small

35171: SMC FS: Internal error while processing the additional paramters

35172: SMC FS: Homing – RefSwitch is connected but ReqHoming not

35173: SMC FS: Additional safety parameters: Invalid axis type ID

35174: SMC FS: Additional safety parameters: Invalid structure version

35175: SMC: Safely Limited Acceleration – Violation of the acceleration monitoring

35176: SMC: Safe Brake Test – SBT: Timeout

35177: SMC: Safe Brake Test – SBT: SBC is active

35178: SMC: Safe Brake Test – Illegal sector change

35179: SMC: additional parameters – Error during download

35180: SMC FFS: RSP – Homing, stored position invalid

35181: SMC: Safe Brake Test – Rho has left the actual sector too early

35182: SMC: Safe Brake Test – Measured and parametrized external load differ

35183: SMC: Safe Brake Test – Current fell below parametrized test current threshold

35184: SMC FFS: Drift of raw positions between uP1 and uP2 to big

35185: SMC FFS: internal error

35186: SMC FFS: Encoder not ready

35189: SMC: Safe Brake Test – Violation of the position tolerance

35190: SMC FFS: Encoder error SinCos processing

35191: SMC: Safe Brake Test – Test interval elapsed, test required

35192: SMC: Current sum exeeded tolerance range

35193: SMC: Current sensor range exceeded phase U

35194: SMC: Current sensor range exceeded phase V

35195: SMC: Current sensor range exceeded phase W

35196: SMC: Compensation data incomplete

35197: SMC FFS: SS2, SOS Violation of standstill position tolerance

35198: SMC FFS: Encoder error was detected

35199: SMC FFS: SDI – Violations of the safe direction

35200: SMC FFS: SDI – Violation of the positive direction

35201: SMC FFS: SDI – Violation of the negative direction

35202: SMC FFS: SLI – Violation of standstill speed limit

35203: SMC FFS: SLI – Violation of position window (increments)

35204: SMC FFS: Violation of the actual speed limit

35205: SMC FFS: Violation of the deceleration ramp

35206: SMC FFS: SMS – Violation of the speed limit

35207: SMC FFS: SOS – Violation of the speed limit

35208: SMC FFS: SS2 – Violation of the speed limit

35209: SMC FFS: SLS1 – Violation of the speed limit

35210: SMC FFS: SLS2 – Violation of the speed limit

35211: SMC FFS: SLS3 – Violation of the speed limit

35212: SMC FFS: SLS4 – Violation of the speed limit

35213: SMC FFS: Alive test of set position was not executed

35214: SMC FFS: Warning on output was not acknowledged

35215: SMC FFS: Alive test – Monitoring timeout

35216: SMC FFS: SMP – Homing timeout exceeded

35217: SMC FFS: SMP – Violation of the deceleration ramp

35218: SMC FFS: SLP – Violation of the deceleration ramp

35219: SMC FFS: SMP – Violation of lower SMP limit

35220: SMC FFS: SMP – Violation of upper SMP limit

35221: SMC FFS: SLP – Violation of lower SLP limit

35222: SMC FFS: SLP – Violation of upper SLP limit

35223: SMC FFS: SMP – Movement in neg. direction outside SMP limit

35224: SMC FFS: SMP – Movement in pos. direction outside SMP limit

35225: SMC FFS: SLP requested, axis is not homed yet

35226: SMC FFS: SMP, SLP – Internal error

35227: SMC FFS: SMP, SLP – INT32 overflow of S_SafePosition

35228: SMC FFS: Homing – Timeout elapsed

35229: SMC FFS: Homing – Standstill Speed tolerance violated

35230: SMC FFS: Homing reference pulse – Max. trigger speed exceeded

35231: SMC FFS: Homing – Movement invalid

35232: SMC FFS: Homing offset – Position outside INT32 range

35233: SMC FFS: Homing offset – Violation of safe encoder range

35234: SMC: Encoder mismatch – Length of encoder configuration data changed

35235: SMC: Encoder mismatch – Serial number of encoder changed

35236: SMC: Encoder mismatch – Version changed or no encoder data stored

35237: SMC: Encoder mismatch – EnDat master data or encoder data changed

35238: SMC: Encoder – EnDat Master state error register is set

35239: SMC FFS: Homing failed

35240: SMC FFS: Violation of safety function

35241: SMC FFS: Function block switched back into IDLE state

35243: SMC FFS: Safe output – Teststate has changed

35244: SMC: Encoder – Received position not valid

35245: SMC: Encoder mismatch detected

35246: SMC: Encoder – Initialization error

35247: SMC: Debug information

35248: SMC: Internal warning, Lockbit set

35249: SMC: Encoder – SafeSpeed exceeded INT16 range

35250: SMC: Encoder – EnDat Master encoder error register is set

35251: SMC: Velocity error limit exceeded

35252: SMC: Position lag error limit exceeded

35253: SMC: Encoder – Rounding error due to parametrization

35254: SMC: Encoder – Length of physical reference system too large

35255: SMC FS: Encoder – Acceleration limit exceeded

35256: SMC: Information read out in encoder error state register.

35257: SMC: Quality monitoring low value warning.

35258: SMC: Timeout error within the HIPERFACE DSL communication.

35259: SMC: Encoder – Error during cyclic operation of the encoder.

35260: SMC: Encoder – Error during error handling of the encoder.

35484: SMC: Encoder not ready

35485: SMC FFS: SafeUserData – Error during requested function SafeUserData

35486: SMC: Safe torque invalid

35487: SMC: Functional phasing state is reset

35488: SMC: Request SS1 – Position/speed evaluation is not ready

35489: SMC: Request SLS1 – Position/speed evaluation is not ready

35490: SMC: Request SLS2 – Position/speed evaluation is not ready

35491: SMC: Request SLS3 – Position/speed evaluation is not ready

35492: SMC: Request SLS4 – Position/speed evaluation is not ready

35493: SMC: Functional encoder changed to error state

35494: SMC: Controller switch on detected, but state of functional encoder invalid.

35495: SMC: SSO configuration error. The encode mode is invalid.

35496: SMC: Current measurement invalid

35497: SMC: BM – Delay time expired

35498: SMC: SSO – A limitation of the observed acceleration is not possible

35499: SMC FFS: Current measurement error was detected

35500: SMC: SSO – Safe speed observer speed error

35501: SMC: SSO – Safe speed observer speed error

35502: SMC: UTILS – Testinterface, dummy logbook entry

35503: SMC FFS: Internal error in ADC conversion

35504: SMC FFS: RSP – Homing, INT32 overflow of S_SafePosition

35505: SMC FFS: SLT – Violation of torque limit

35506: SMC FFS: RSP – Homing, Positional change during power off too big

35507: SMC FFS: RSP – Homing, Config changed

35508: SMC FFS: Internal error, FPGA communication

35509: SMC FFS: RSP – Homing, CRC error while receiving the remanent safe position

35510: SMC FFS: RSP – Homing, Homing already done without RSP

35511: SMC: RSP – State RSP Valid changed during safe operation

36001: Parameter limited to valid range

36002: Total time for the position loop controller limited to prediction time

36003: Braking distance exceeds positive SW limit – Deceleration parameter increased

36004: Braking distance exceeds negative SW limit – Deceleration parameter increased

36005: Warning triggered by command

37101: Calculated compensation distance on slave axis limited to maximum

37102: Calculated compensation distance on slave axis limited to minimum

37108: Calculated compensation distance of master axis limited to minimum

37111: Cam data: Difference between polynomial value y(xn) and slave period

37112: Polynomial within cam data exceeds limit value

37113: Compensation gear: Limit values exceeded

38001: Torque limiter: Limit value higher than maximum value

38003: Motor holding brake: Test torque was limited

38004: Motor holding brake: Test torque less than load torque

38005: Motor test: Speed is too high during switch on

38006: Current controller: Permissible current offset values exceeded

38008: Bleeder: No current flow

38009: Inverter: Output: Current flow test aborted

39000: Encoder: Warning active

39001: Encoder: Position correction active

39002: Resolver: Speed limit for 14 bit resolution exceeded

39003: EnDat encoder: Alarm bit is set

39004: EnDat encoder: Alarm bit – Lighting failure

39005: EnDat encoder: Alarm bit – Signal amplitude too small

39006: EnDat encoder: Alarm bit – Position value contains an error

39007: EnDat encoder: Alarm bit – Overvoltage

39008: EnDat encoder: Alarm bit – Undervoltage

39009: EnDat encoder: Alarm bit – Overcurrent

39010: EnDat encoder: Alarm bit – Battery change required

39011: EnDat encoder: Warning bit – Frequency too high

39012: EnDat encoder: Warning bit – Temperature too high

39013: EnDat encoder: Warning bit – Lighting reserve reached

39014: EnDat encoder: Warning bit – Battery charge too low

39015: EnDat encoder: Warning bit – Reference point not reached

39016: Incremental encoder emulation: Frequency too high

39017: Encoder: CRC error while reading position

39018: Reference pulse monitoring: Faulty position, resolution, or reference pulse

39019: Serial encoder interface: Stop bit error

39020: Serial encoder interface: Receive data overrun

39021: Serial encoder interface: Send data error

39022: EnDat encoder: Warning bit is set

39023: EnDat encoder: CRC error while reading EnDat2.2 additional information

39024: EnDat encoder: Operating status error sources: M ALL Power down

39025: EnDat encoder: Operating status error sources: M Overflow / Underflow

39026: EnDat encoder: Type 3 error while reading EnDat2.2 additional information

39027: Encoder Emulation: power supply fail

39028: Encoder: Multiturn failure

39029: Encoder: Battery charge too low

39030: Encoder: Warning bit is set

39032: EnDat encoder: Operating status error sources: Lighting

39033: EnDat encoder: Operating status error sources: Signal amplitude

39034: EnDat encoder: Operating status error sources: S Pos 1

39035: EnDat encoder: Operating status error sources: Overvoltage

39036: EnDat encoder: Operating status error sources: Undervoltage

39037: EnDat encoder: Operating status error sources: over current

39038: EnDat encoder: Operating status error sources: Temperature exceeded

39039: EnDat encoder: Operating status error sources: S Pos

39040: EnDat encoder: Operating status error sources: S sytem

39041: EnDat encoder: Operating status error sources: S ALL power down

39042: EnDat encoder: Operating status error sources: M Pos 1

39043: EnDat encoder: Operating status error sources: M Pos 2

39044: EnDat encoder: Operating status error sources: M System

39045: EnDat encoder: Operating status error sources: M battery

39046: Encoder: Incorrect encoder address acknowledgment

39047: Encoder: Position value not synchronous with absolute value

39048: Encoder: Incorrect command code acknowledgment

39049: Encoder: Timeout during parameter transfer

39050: Encoder: Parity

39051: Encoder: Hiperface error bit

39052: Encoder: Measurement range exceeded

39053: Encoder: Internal check of the encoder interface failed

39054: Encoder: Invalid supply voltage

39055: Encoder: Incremental signal amplitude too small

39056: Encoder: Incremental signal amplitude too large

39059: Encoder: Status message

39060: Encoder: Sync bit error

39061: Encoder: UART Transmission error

39086: Encoder: Register address

39087: Encoder: Register data

39088: Encoder: HIPERFACE DSL: Online status: Bit 4: ANS: Incorrect answer detected

39089: Encoder: HIPERFACE DSL: Online status: Bit 10: VPOS: Safe position invalid

39090: Encoder: HIPERFACE DSL: Online status: Bit 11: POS: Estimator turned on

39091: Encoder: HIPERFACE DSL: Online status: Bit 13: SCE: CRC error Safe Channel

39092: EnDat encoder: Warning bit – cyclical operation

39093: EnDat encoder: Warning bit – boundary layer not reached

39094: EnDat encoder: Warning bit – not ready

39095: EnDat encoder: Warning bit – diagnostic threshold below

39301: Analog/Digital IO: 24V power supply fail

39302: Digital IO 1-4: Diagnose bit active (current, 24V supply)

39303: Digital IO 5-8: Diagnose bit active (current, 24V supply)

39305: Digital IO 10: Diagnose bit active (current, temperature)

39306: Digital IO 9: Diagnose bit active (current, temperature)

39307: Digital IO: Outputs deactivated by output mask after network error

39308: Analog/Digital IO: Diagnose bit active

39309: Digital IO: Digital output: Diagnose bit active

39310: Analog IO: Analog output: Diagnose bit active

39311: Analog IO: Analog input: Input disturbed

39312: Analog IO: Analog input: Analog value smaller than minimum value

39313: Analog IO: Analog input: Analog value greater than maximum value

39314: Analog IO: Analog input: Analog value below the measuring range

39315: Analog IO: Analog input: Analog value above the measuring range

39316: Analog IO: Analog input: Analog value corrupted

39317: Analog IO: Analog output: Input value outside the validity range

39500: Encoder: HIPERFACE: Status: Incorrect alignment data (01h)

39501: Encoder: HIPERFACE: Status: Sensor not adjusted or in adjustment mode (20h)

39502: Encoder: HIPERFACE: Status: Distance measure/sensor too high (21h)

39504: Encoder: HIPERFACE: Status: Linear position fault (23h)

39510: Encoder: HIPERFACE: Status: The encoder has not detected any faults (00h)

39511: Encoder: HIPERFACE: Status: Analog signals outside specification (01h)

39512: Encoder: HIPERFACE: Status: Incorrect internal angular offset (02h)

39513: Encoder: HIPERFACE: Status: Data field partitioning table destroyed (03h)

39514: Encoder: HIPERFACE: Status: Analog limit values not available (04h)

39515: Encoder: HIPERFACE: Status: Internal I²C bus not operational (05h)

39516: Encoder: HIPERFACE: Status: Internal checksum error (06h)

39517: Encoder: HIPERFACE: Status: Program watchdog fault (07h)

39518: Encoder: HIPERFACE: Status: Counter overflow (08h)

39519: Encoder: HIPERFACE: Status: Parity error (09h)

39520: Encoder: HIPERFACE: Status: Checksum error (0Ah)

39521: Encoder: HIPERFACE: Status: Unknown command (0Bh)

39522: Encoder: HIPERFACE: Status: Wrong command length (0Ch)

39523: Encoder: HIPERFACE: Status: Wrong command argument (0Dh)

39524: Encoder: HIPERFACE: Status: Read-only data field (0Eh)

39525: Encoder: HIPERFACE: Status: Incorrect access code (0Fh)

39526: Encoder: HIPERFACE: Status: Out of memory fault (10h)

39527: Encoder: HIPERFACE: Status: Wrong data field offset (11h)

39528: Encoder: HIPERFACE: Status: Wrong data field number (12h)

39538: Encoder: HIPERFACE: Status: Value monitoring analog signals (1Ch)

39539: Encoder: HIPERFACE: Status: Transmitter current critical (1Dh)

39540: Encoder: HIPERFACE: Status: Encoder temperature critical (1Eh)

39541: Encoder: HIPERFACE: Status: Speed too high (1Fh)

39542: Encoder: HIPERFACE: Status: Singleturn position unreliable (20h)

39543: Encoder: HIPERFACE: Status: Multiturn amplitude fault (21h)

39544: Encoder: HIPERFACE: Status: Multiturn sync fault (22h)

39545: Encoder: HIPERFACE: Status: Multiturn vectorlength fault (23h)

39546: Encoder: HIPERFACE: Status: Multiturn counter fault (24h)

39594: Encoder: HIPERFACE DSL: Encoder status: Plausibility Error (ST0:4)

39596: Encoder: HIPERFACE DSL: Encoder status: Improper Configuration Error (ST0:6)

39597: Encoder: HIPERFACE DSL: Encoder status: Crosscheck Error (ST0:7)

39600: Encoder: HIPERFACE DSL: Encoder status: Protocol Reset Indication (ST0:0)

39601: Encoder: HIPERFACE DSL: Encoder status: Acceleration Overflow Error (ST0:1)

39602: Encoder: HIPERFACE DSL: Encoder status: Test Running (ST0:2)

39603: Encoder: HIPERFACE DSL: Encoder status: Drift Compensation Error (ST0:3)

39604: Encoder: HIPERFACE DSL: Encoder status: Position Tracking Filter Error (ST0:4)

39605: Encoder: HIPERFACE DSL: Encoder status: Position Vector Length Error (ST0:5)

39606: Encoder: HIPERFACE DSL: Encoder status: Counter Error (ST0:6)

39607: Encoder: HIPERFACE DSL: Encoder status: Position Synchronization Error (ST0:7)

39610: Encoder: HIPERFACE DSL: Encoder status: Singleturn Error (ST1:0)

39611: Encoder: HIPERFACE DSL: Encoder status: Multiturn Amplitude Error (ST1:1)

39612: Encoder: HIPERFACE DSL: Encoder status: Multiturn Sync Error (ST1:2)

39613: Encoder: HIPERFACE DSL: Encoder status: Multiturn Vector Length Error (ST1:3)

39614: Encoder: HIPERFACE DSL: Encoder status: Position Crosscheck Error (ST1:4)

39620: Encoder: HIPERFACE DSL: Encoder status: Power-on Self-test Conducted (ST2:0)

39621: Encoder: HIPERFACE DSL: Encoder status: Safety Parameter Warning (ST2:1)

39622: Encoder: HIPERFACE DSL: Encoder status: Safety Parameter Error (ST2:2)

39623: Encoder: HIPERFACE DSL: Encoder status: Standard Parameter Error (ST2:3)

39624: Encoder: HIPERFACE DSL: Encoder status: Internal Communication Error 1 (ST2:4)

39625: Encoder: HIPERFACE DSL: Encoder status: Internal Communication Error 2 (ST2:5)

39626: Encoder: HIPERFACE DSL: Encoder status: Internal System Error (ST2:6)

39630: Encoder: HIPERFACE DSL: Encoder status: Critical Temperature (ST3:0)

39631: Encoder: HIPERFACE DSL: Encoder status: Critical LED Current (ST3:1)

39632: Encoder: HIPERFACE DSL: Encoder status: Critical Supply Voltage (ST3:2)

39633: Encoder: HIPERFACE DSL: Encoder status: Critical Rotation Speed (ST3:3)

39634: Encoder: HIPERFACE DSL: Encoder status: Critical Acceleration (ST3:4)

39635: Encoder: HIPERFACE DSL: Encoder status: Counter Overflow (ST3:5)

39636: Encoder: HIPERFACE DSL: Encoder status: Internal Monitoring Error (ST3:6)

39638: Encoder: HIPERFACE DSL: Encoder status: Critical Rotor Position (ST3:1)

39640: Encoder: HIPERFACE DSL: Encoder status: Invalid access (ST4:0)

39641: Encoder: HIPERFACE DSL: Encoder status: Access denied (ST4:1)

39642: Encoder: HIPERFACE DSL: Encoder status: Resource access error (ST4:2)

39643: Encoder: HIPERFACE DSL: Encoder status: File access error (ST4:3)

39670: Encoder: HIPERFACE DSL: Encoder status: User defined warning (ST7:0)

39671: Encoder: HIPERFACE DSL: Encoder status: User defined warning (ST7:1)

39672: Encoder: HIPERFACE DSL: Encoder status: User defined warning (ST7:2)

39673: Encoder: HIPERFACE DSL: Encoder status: User defined warning (ST7:3)

39674: Encoder: HIPERFACE DSL: Encoder status: User defined warning (ST7:4)

39675: Encoder: HIPERFACE DSL: Encoder status: User defined warning (ST7:5)

39676: Encoder: HIPERFACE DSL: Encoder status: User defined warning (ST7:6)

39677: Encoder: HIPERFACE DSL: Encoder status: User defined warning (ST7:7)

41001: Heatsink temperature sensor: Warning limit exceeded

41002: Heatsink temperature sensor: Not connected or damaged

41011: Temperature sensor (Motor|Choke|External): Warning limit exceeded

41031: Junction temperature model: Warning limit exceeded

41041: Bleeder temperature model: Warning limit exceeded

41051: ACOPOS peak current: Warning limit exceeded

41061: ACOPOS continuous current: Warning limit exceeded

41070: Motor temperature model: Warning limit exceeded

41075: ACOPOS continuous power: Warning limit exceeded

41078: Power stage: Temperature sensor 1: Warning limit exceeded

41080: Pre-charging resistor temperature model: Warning limit exceeded

41081: Power stage temperature model: Warning limit exceeded

41083: Power stage: Temperature sensor 2: Warning limit exceeded

41085: Power stage: Temperature sensor 3: Warning limit exceeded

41087: Power stage: Temperature sensor 4: Warning limit exceeded

41089: Encoder temperature sensor: Warning limit exceeded

41090: 24V Supply/Main relay temperature sensor: Warning limit exceeded

41091: Power stage: Temperature sensor 5: Warning limit exceeded

41092: Rectifier temperature model: Warning limit exceeded

41093: DC bus relay temperature model: Warning limit exceeded

41094: DC bus capacitor temperature model: Warning limit exceeded

41095: DC bus: Continuous total power: Warning limit exceeded

41096: DC bus: Peak total power: Warning limit exceeded

41097: DC connector temperature model: Warning limit exceeded

41098: Power stage: Temperature sensor: Warning limit exceeded

41099: Motor temperature model: Warning limit exceeded

41100: Motor: Temperature sensors: Temperature difference to high

41101: Power stage: Temperature sensor 1: Under temperature: Warning limit exceeded

64002: Delay before SW Reset (network with ascending node numbers ?)

64003: Delay before NC System Start (network with ascending node numbers ?)

64004: The following boot error could be entered here with a delay

64005: Timeout for parameter enable after start of operating system

64006: Drive did not become synchronous with network master

64007: Timeout for enable of acyclic network communication

64008: Timeout for enable of cyclic network communication

64009: Acp10cfg contains a POWERLINK interface, for which no axis is defined

64010: NC software test version (validity period in Logger)

64011: Timeout for completion of encoder initialization

64012: NCSYS does not contain an operating system for this ACOPOS hardware type

64013: The basis initialization was aborted due to an error

64014: No integral cycle time ratio between NetCyc and POWERLINK

64015: No integral cycle time ratio between NetCyc and POWERLINK

64016: Name of SDC axis configuration PV is too long (PV is not used)